Compacta MR30

Slip-on geared motor Compacta MR30

Standard:

  • 3-phase AC motor
  • Terminal box
  • Any transmission
  • Thermal protection
  • IP 54
  • Plastic 1st gear stage

Depending on the gear ratio, the Compacta MR30 shaft-mounted gear motor with the optional integrated control unit version provides an output speed of 2.6 to 123.4 rpm and a nominal torque up to 221 lbs ft. The drive motor has a compact design, making it ideal for applications in reversing mode with narrow installation conditions. Standard drive motors are splash-protected (IP54), optionally jet-protected (IP65) and explosion-protected in accordance with ATEX 95. Additional options increase the number of application options substantially.

Furthermore, design-related adjustments are also conceivable for larger quantities so that the drive motor can be adapted individually to certain requirements. You can find projects that have already been implemented here.

The Compacta series covers output speeds of 0.45 to 193 rpm and a torque range of 8 to 1180 lbs ft with the four sizes MR6, MS12, MR30 and AG160.

Dimensions for standard drive

Dimensional drawing for Slip-on geared motor Compacta MR30

mm to inch converter

Options

Slip-on geared motor Compacta MR30 Options
Options with dimensions [mm] a b
Single phase AC motor (-) (-)
DC motor (-) 239 (9.41″)
Motor disc brake (-) 244 (9.61″)
Hand crank (-) 380 (14.96″)
Limit switch version 1 218 (8.58″) (-)
Limit switch version 2 / 2P (-) (-)

(-) Does not affect size
(x) Please refer to the datasheets for additional or missing dimensions

3-phase AC motors – 3×230/400VAC-60Hz

Output speed

n2 rpm

Output torque

lbs ft

duty cycle 45%

Gear reduction

ratio

Motor speed

n1 rpm

Motor output

kW

duty cycle 45%

Self

locking

Max. limit switch range

Output rotation *

normal

long

148 37 22.7:1 3360 1.5 So 260 430
74.0 69 45.4:1 3360 1.5 So 130 215
46.8 101 71.8:1 3360 1.5 So 85 135
37.0 77 45.4:1 1680 0.8 So 130 215
34.2 114 98.3:1 3360 1.5 So 60 100
26.1 135 128.5:1 3360 1.5 Ss 47 77
23.4 110 71.8:1 1680 0.8 So 85 135
18.5 147 181.4:1 3360 1.5 Ss 32 55
17.1 126 98.3:1 1680 0.8 So 60 100
14.1 165 238.1:1 3360 1.5 Sd 25 42
12.7 153 264.6:1 3360 1.5 Sd 23 38
9.3 163 181.4:1 1680 0.8 Ss 32 55
7.1 184 238.1:1 1680 0.8 Sd 25 42
6.3 170 264.6:1 1680 0.8 Sd 23 38
4.6 91 (33% ED) 181.4:1 840 0.2 (33% ED) Ss 32 55
3.5 104 (33% ED) 238.1:1 840 0.2 (33% ED) Sd 25 42
3.2 98 (33% ED) 264.6:1 840 0.2 (33% ED) Sd 23 38

So = no self locking; Ss = static self locking; Sd= dynamic self locking

3-phase AC motors – 3×265/460VAC-60Hz

Output speed

n2 rpm

Output torque

lbs ft

duty cycle 45%

Gear reduction

ratio

Motor speed

n1 rpm

Motor output

kW

duty cycle 45%

Self

locking

Max. limit switch range

Output rotation *

normal

long

148 44 22.7:1 3360 1.7 So 260 430
74.0 83 45.4:1 3360 1.7 So 130 215
46.8 122 71.8:1 3360 1.7 So 85 135
37.0 92 45.4:1 1680 0.9 So 130 215
34.2 138 98.3:1 3360 1.7 So 60 100
26.1 162 128.5:1 3360 1.7 Ss 47 77
23.4 133 71.8:1 1680 0.9 So 85 135
18.5 177 181.4:1 3360 1.7 Ss 32 55
17.1 152 98.3:1 1680 0.9 So 60 100
14.1 199 238.1:1 3360 1.7 Sd 25 42
12.7 184 264.6:1 3360 1.7 Sd 23 38
9.3 197 181.4:1 1680 0.9 Ss 32 55
7.1 221 238.1:1 1680 0.9 Sd 25 42
6.3 205 264.6:1 1680 0.9 Sd 23 38
4.6 109 (33% ED) 181.4:1 840 0.2 (33% ED) Ss 32 55
3.5 125 (33% ED) 238.1:1 840 0.2 (33% ED) Sd 25 42
3.2 118 (33% ED) 264.6:1 840 0.2 (33% ED) Sd 23 38

So = no self locking; Ss = static self locking; Sd= dynamic self locking

3-phase AC motors – 3×120/208VAC-60Hz

Output speed

n2 rpm

Output torque

lbs ft

duty cycle 45%

Gear reduction

ratio

Motor speed

n1 rpm

Motor output

kW

duty cycle 45%

Self

locking

Max. limit switch range

Output rotation *

normal

long

148 44 22.7:1 3360 1.77 So 260 430
74.0 83 45.4:1 3360 1.77 So 130 215
46.8 122 71.8:1 3360 1.77 So 85 135
34.2 138 98.3:1 3360 1.77 So 60 100
26.1 162 128.5:1 3360 1.77 Ss 47 77
18.5 177 181.4:1 3360 1.77 Ss 32 55
14.1 199 238.1:1 3360 1.77 Sd 25 42
12.7 184 264.6:1 3360 1.77 Sd 23 38

So = no self locking; Ss = static self locking; Sd= dynamic self locking

Single phase AC motors – 1x110VAC-60Hz

Output speed
n2 rpm
Output torque
lbs ft (40% duty cycle) **
Gear reduction
ratio
Motor speed
n1 rpm
Motor output
kW
Self
locking
148 26.6 22.7:1 3360 1.06 So
74.0 49.6 45.4:1 3360 1.06 So
46.8 73.0 71.8:1 3360 1.06 So
34.0 89.4 98.8:1 3360 1.06 So
26.1 97.4 128.5:1 3360 1.06 Ss
18.4 106.2 181.4:1 3360 1.06 Ss
14.1 119.5 238.1:1 3360 1.06 Sd
12.7 110.6 246.6:1 3360 1.06 Sd

So = no self locking; Ss = static self locking; Sd= dynamic self locking
** The stated single phase torques are operational torques. The starting torque may be only 66% of the stated catalog torque. Please contact the manufacturer if max. torque is required.

24V DC shunt wound motor

Output speed
n2 rpm
Output torque
lbs ft
Self locking Gear reduction
ratio
66 38.4 So 22.7:1
33 71.5 So 45.4:1
21 104.0 So 71.8:1
15 119.5 So 98.3:1
11.5 140.1 Ss 128.5:1
8 151.2 Ss 181.4:1
6.5 162.3 Sd 238.1:1
5.5 147.5 Sd 264.6:1

So = no self locking; Ss = static self locking; Sd= dynamic self locking
P = 0.67 hp
IN = 30A
40% duty cycle
The output speed of Compacta gear motors with DC motors varies with the output torque.

Please note: The gear motor can be overloaded by 50% for brief periods. Single-phase AC and DC motors may stall.

Please contact the manufacturer regarding the following operating conditions:
• Temperatures below 32°F (single phase AC and DC motors: below 50°F)
• Temperatures above 104°F
• Strong vibrations

Additional information

Contact person

Customized designs

Application examples

Compacta overview